Disable settings inapplicable for the current timekeeping mode

This commit is contained in:
Jonathan G Rennison
2024-02-16 17:55:35 +00:00
parent 75645b8563
commit bd74340416
3 changed files with 43 additions and 2 deletions

View File

@@ -782,6 +782,9 @@ STR_CONFIG_SETTING_TIMETABLE_IN_TICKS_HELPTEXT :Show travel tim
STR_CONFIG_SETTING_PATHFINDER_FOR_TRAINS_HELPTEXT_EXTRA :{STRING}{}Various features require use of the YAPF pathfinder, including: routing restrictions (all pathfinder and reservation related actions), reverse at waypoint/signal and drive through train depots.
STR_CONFIG_SETTING_DISABLED_TIMEKEEPING_MODE_CALENDAR :{RED}[Setting disabled in calendar timekeeping mode]
STR_CONFIG_SETTING_DISABLED_TIMEKEEPING_MODE_WALLCLOCK :{RED}[Setting disabled in wallclock timekeeping mode]
STR_CHEAT_EDIT_MONEY_QUERY_CAPT :{WHITE}Increase or decrease money
STR_CHEAT_INFLATION_COST :{LTBLUE}Change inflation cost factor: {ORANGE}{DECIMAL}
STR_CHEAT_INFLATION_COST_QUERY_CAPT :{WHITE}Change inflation cost factor

View File

@@ -2259,7 +2259,7 @@ static bool TownCargoScaleGUI(SettingOnGuiCtrlData &data)
{
switch (data.type) {
case SOGCT_VALUE_DPARAMS:
SetDParam(data.offset, STR_CONFIG_SETTING_CARGO_SCALE_VALUE_MONTHLY + GetGameSettings().economy.town_cargo_scale_mode);
if (!EconTime::UsingWallclockUnits(_game_mode == GM_MENU)) SetDParam(data.offset, STR_CONFIG_SETTING_CARGO_SCALE_VALUE_MONTHLY + GetGameSettings().economy.town_cargo_scale_mode);
return true;
default:
@@ -2276,7 +2276,7 @@ static bool IndustryCargoScaleGUI(SettingOnGuiCtrlData &data)
return true;
case SOGCT_VALUE_DPARAMS:
SetDParam(data.offset, STR_CONFIG_SETTING_CARGO_SCALE_VALUE_MONTHLY + GetGameSettings().economy.industry_cargo_scale_mode);
if (!EconTime::UsingWallclockUnits(_game_mode == GM_MENU)) SetDParam(data.offset, STR_CONFIG_SETTING_CARGO_SCALE_VALUE_MONTHLY + GetGameSettings().economy.industry_cargo_scale_mode);
return true;
default:
@@ -2292,6 +2292,38 @@ static bool IndustryCargoScaleModeGUI(SettingOnGuiCtrlData &data)
data.text = STR_CONFIG_SETTING_INDUSTRY_CARGO_SCALE_MODE_HELPTEXT_EXTRA;
return true;
default:
return WallclockModeDisabledGUI(data);
}
}
static bool CalendarModeDisabledGUI(SettingOnGuiCtrlData &data)
{
switch (data.type) {
case SOGCT_VALUE_DPARAMS:
if (!EconTime::UsingWallclockUnits(_game_mode == GM_MENU)) SetDParam(data.offset, STR_CONFIG_SETTING_DISABLED_TIMEKEEPING_MODE_CALENDAR);
return true;
case SOGCT_GUI_DISABLE:
if (!EconTime::UsingWallclockUnits(_game_mode == GM_MENU)) data.val = 1;
return true;
default:
return false;
}
}
static bool WallclockModeDisabledGUI(SettingOnGuiCtrlData &data)
{
switch (data.type) {
case SOGCT_VALUE_DPARAMS:
if (EconTime::UsingWallclockUnits(_game_mode == GM_MENU)) SetDParam(data.offset, STR_CONFIG_SETTING_DISABLED_TIMEKEEPING_MODE_WALLCLOCK);
return true;
case SOGCT_GUI_DISABLE:
if (EconTime::UsingWallclockUnits(_game_mode == GM_MENU)) data.val = 1;
return true;
default:
return false;
}

View File

@@ -25,6 +25,8 @@ static bool OrderTownGrowthRate(SettingOnGuiCtrlData &data);
static bool TownCargoScaleGUI(SettingOnGuiCtrlData &data);
static bool IndustryCargoScaleGUI(SettingOnGuiCtrlData &data);
static bool IndustryCargoScaleModeGUI(SettingOnGuiCtrlData &data);
static bool CalendarModeDisabledGUI(SettingOnGuiCtrlData &data);
static bool WallclockModeDisabledGUI(SettingOnGuiCtrlData &data);
static const SettingTable _economy_settings{
[post-amble]
@@ -234,6 +236,7 @@ strval = STR_JUST_COMMA
post_cb = DayLengthChanged
cat = SC_BASIC
extver = SlXvFeatureTest(XSLFTO_AND, XSLFI_VARIABLE_DAY_LENGTH)
guiproc = WallclockModeDisabledGUI
patxname = ""variable_day_length.economy.day_length_factor""
[SDT_BOOL]
@@ -736,6 +739,7 @@ strval = STR_CONFIG_SETTING_MINUTES_PER_YEAR_VALUE
pre_cb = [](auto) { return _game_mode == GM_MENU || _settings_game.economy.timekeeping_units == 1; }
post_cb = ChangeMinutesPerYear
cat = SC_BASIC
guiproc = CalendarModeDisabledGUI
[SDT_VAR]
var = economy.town_cargo_scale
@@ -778,6 +782,7 @@ strhelp = STR_CONFIG_SETTING_CARGO_SCALE_MODE_HELPTEXT
strval = STR_CONFIG_SETTING_CARGO_SCALE_MODE_MONTHLY
cat = SC_BASIC
post_cb = [](auto) { InvalidateWindowClassesData(WC_GAME_OPTIONS); UpdateCargoScalers(); }
guiproc = WallclockModeDisabledGUI
[SDT_VAR]
var = economy.industry_cargo_scale_mode
@@ -841,6 +846,7 @@ strhelp = STR_CONFIG_SETTING_TICK_RATE_HELPTEXT
strval = STR_CONFIG_SETTING_TICK_RATE_TRADITIONAL
cat = SC_EXPERT
post_cb = [](auto) { SetupTickRate(); }
guiproc = WallclockModeDisabledGUI
patxname = ""economy.tick_rate""
## Old settings